Output Current:
* Setting Range
* Setting Resolution
* Hold Stability
* Readout Resolution (IEEE)
0 to rated current (120 AMps
200 micro amps
2 ppm/hr/C
20 mirco amps
Output Voltage:
0-10 Volts 10mA/Sec
Digitally Set Smooth Ramp:
Any ramp rate in the range.
Setting accuracy.
10 amp to 10 Micro-amp / second
0.5% of ramp set.
Switch Heater:
Setting Range
Setting Resolution
Maximum Current
0 to 5.0V
0.1V
100mA.